Kitchen Installers UK

Cooker hood installation · England

Cooker hood installation in Greater London

Our cooker hood installation work covers the whole of Greater London, including Brent, Islington and Westminster.

Guide price£160 to £1,200
Towns covered106 towns, including Brent
Timescale3 to 7 hours for most hoods
A fitter on a step ladder fixing a stainless steel chimney cooker hood above a hob, with ducting visible above

When does cooker hood installation make sense in Greater London?

If your Greater London kitchen has an older open-flued boiler, fitting a stronger hood needs care, as it can affect the flue and should be followed by a spillage test.

If condensation runs down the windows of your Greater London kitchen whenever you cook, the hood may be recirculating, undersized or ducted through a long, flexible run.

What does cooker hood installation in Greater London include?

Here is what usually goes into cooker hood installation, adjusted to your Greater London kitchen after we have measured it:

  • Survey of the hob position, duct route, outside wall and any open-flued appliance
  • Hood fixed at the height set by the hood and hob manufacturers
  • Core drilling through the outside wall and an external grille fitted and sealed
  • Short, straight runs of rigid ducting wherever the route allows
  • Island and ceiling hoods fixed into the ceiling structure by two people
  • Recirculating hoods fitted with carbon filters, and their limits explained
  • Power supply connected by an electrician and tested to BS 7671
  • Spillage test by a Gas Safe registered engineer where an open-flued appliance is present

How much does cooker hood installation cost in Greater London?

Typical cooker hood installation prices for homes in Greater London, including VAT and adjusted for London. Your own figure depends on the size of the kitchen, the layout and what is moving. Expect costs in London to sit somewhat above UK averages, reflecting local labour rates.

How much does cooker hood installation cost in Greater London?
Typical projectGuide price
Like-for-like cooker hood swapSame position and ducting£160–£310
New ducted hood through an outside wallCore drilling, ducting run and external grille£390–£1,200
Island or ceiling hood installedTwo-person install, fixings to the ceiling structure£390–£820
Recirculating hood fittedNo ducting; carbon filters need replacing£160–£390

Guide ranges cover fitting and connection with standard ducting through a straightforward wall; long or concealed duct runs, ceiling repairs, new electrical spurs, spillage tests and the hood itself are priced separately. Prices include VAT at 20%.

Kitchens in homes across Greater London

The housing mix across Greater London includes Victorian and Edwardian terraces, conversion flats, mansion block flats and 1930s semis, so no two kitchen fits are quite alike. Victorian terraces often have a narrow galley beside the side return, while conversion flats and mansion blocks usually fit the kitchen into a small room or along one living-room wall.

London's mains water is hard, so limescale builds quickly on taps and boiling water taps, and a scale-reducing filter is worth planning in. Permit parking, red routes and flats without lifts are common, so parking suspensions, stair carries and lift bookings may need arranging before delivery day.

Opening a narrow galley into the dining room or side return is one of the most common terrace projects in London. Leasehold flats often call for a full kitchen in a small space, worked around building rules on noise, working hours and waste.

Rules for cooker hood installation in Greater London

In England, Approved Document F guidance for kitchen extract is about 30 litres per second from a cooker hood extracting outside, or 60 litres per second from a fan elsewhere in the room. A recirculating hood does not remove moisture, so another means of extract is usually needed. A new vent through the outside wall of a flat may need planning permission and the freeholder's consent, and an open-flued gas appliance in the room calls for a spillage test.

Conservation areas are widespread across London, so a new extractor vent on a front wall may need permission, and leaseholders usually need the freeholder's written consent first.

Before you start

  • Check the minimum height above the hob in both the hood and hob instructions, and use the greater of the two figures.
  • In a flat or a listed building, check what consents are needed before any hole is cut through an outside wall.
  • Choose ducted extraction where you can; a recirculating hood filters grease and smells but leaves the moisture from cooking in the room.
  • If the kitchen has an open-flued boiler or gas fire, a Gas Safe registered engineer should carry out a spillage test after the hood is fitted.
  • If your Greater London home is listed, or in a building with strict rules on outside changes, check what is allowed before any hole is cut for a duct.
  • Choose a hood at least as wide as your hob, and compare its stated extraction rate with the size of the room before you buy.

Questions about cooker hood installation in Greater London

How much does cooker hood installation cost in Greater London?

Guide prices in Greater London are about £160 to £310 including VAT for a like-for-like cooker hood swap. The final price depends on the size of the kitchen and what is moving, and is set out in an itemised written quote.

Do you cover the whole of Greater London?

Yes. We carry out cooker hood installation across Greater London, including Brent, Islington, Westminster and Bexley. Every job starts with a free survey visit and an itemised written quote.

Should I choose a ducted or a recirculating cooker hood?

A ducted hood is usually more effective, because it takes steam, smoke and smells outside. A recirculating hood passes air through grease and carbon filters and returns it to the room, so it deals with grease and smells but not moisture, and another means of extract is usually needed. Recirculating suits kitchens with no practical duct route, and its carbon filters need replacing.

How high should a cooker hood be above the hob?

At least the minimum distance given by the manufacturers. Both the hood and the hob instructions set a minimum gap between them, and where they differ the greater figure should be used. Gas hobs usually need more clearance than induction. A hood fitted too low is a fire risk, while one fitted much higher than recommended captures less steam.

Does a cooker hood need a hole in the wall?

A ducted hood does. The usual route is a core-drilled hole through the nearest outside wall, with rigid ducting from the hood and an external grille sealed into the wall. Where the hob is far from an outside wall, the duct can sometimes run above the wall units or through a ceiling void. A recirculating hood needs no hole, but it removes no moisture.

Cooker hood installation in towns across Greater London

Choose a town for local guide prices and postcode coverage:

Cooker hood installation in nearby areas

Free survey visit

Book a free survey visit in Greater London

We measure up, check walls, floors and service positions, and send an itemised written quote. Or get a guide price online in about two minutes.

Book a free survey visit

Tell us about the kitchen and the work. We will call to arrange a visit.

We use your details only to arrange your visit and quote. See our privacy notice.

Prefer to talk? 0800 088 6341

CallGuide price