Kitchen Installers UK

Cooker hood installation · Greater London

Cooker hood installation in Brent

Looking for cooker hood installation in Brent? We survey, quote and carry out cooker hood installation for homes across Brent and the rest of Greater London, with one contract from the first measure to the final check.

Guide price£160 to £1,200
Postcodes includeHA9
Timescale3 to 7 hours for most hoods
A fitter on a step ladder fixing a stainless steel chimney cooker hood above a hob, with ducting visible above

Is cooker hood installation right for your Brent kitchen?

A new kitchen in a Brent home can move the hob away from the old vent, so the hood, the duct run and the wall grille all need rethinking together.

If your Brent kitchen has an older open-flued boiler, fitting a stronger hood needs care, as it can affect the flue and should be followed by a spillage test. If your home is in Brent or close by in Wembley or Sudbury, Greater London, the same survey, quote and fitting process applies.

What we cover for cooker hood installation in Brent

After the survey visit we write the scope down. For cooker hood installation in Brent it usually covers:

  • Core drilling through the outside wall and an external grille fitted and sealed
  • Power supply connected by an electrician and tested to BS 7671
  • Survey of the hob position, duct route, outside wall and any open-flued appliance
  • Island and ceiling hoods fixed into the ceiling structure by two people
  • Recirculating hoods fitted with carbon filters, and their limits explained
  • Hood fixed at the height set by the hood and hob manufacturers

Guide prices for cooker hood installation in Brent

Typical cooker hood installation prices for homes in Brent, including VAT and adjusted for London. Your own figure depends on the size of the kitchen, the layout and what is moving. Prices in London usually run above the national guide, mainly because labour and parking cost more.

Guide prices for cooker hood installation in Brent
Typical projectGuide price
Like-for-like cooker hood swapSame position and ducting£160–£310
New ducted hood through an outside wallCore drilling, ducting run and external grille£390–£1,200
Island or ceiling hood installedTwo-person install, fixings to the ceiling structure£390–£820
Recirculating hood fittedNo ducting; carbon filters need replacing£160–£390

Guide ranges cover fitting and connection with standard ducting through a straightforward wall; long or concealed duct runs, ceiling repairs, new electrical spurs, spillage tests and the hood itself are priced separately. Prices include VAT at 20%.

Local homes and their kitchens

In and around Brent, homes range across Victorian and Edwardian terraces, conversion flats, mansion block flats and 1930s semis. Victorian terraces often have a narrow galley beside the side return, while conversion flats and mansion blocks usually fit the kitchen into a small room or along one living-room wall.

London's mains water is hard, so limescale builds quickly on taps and boiling water taps, and a scale-reducing filter is worth planning in. Permit parking, red routes and flats without lifts are common, so parking suspensions, stair carries and lift bookings may need arranging before delivery day.

Do you need approval for cooker hood installation in Brent?

In England, Approved Document F guidance for kitchen extract is about 30 litres per second from a cooker hood extracting outside, or 60 litres per second from a fan elsewhere in the room. A recirculating hood does not remove moisture, so another means of extract is usually needed. A new vent through the outside wall of a flat may need planning permission and the freeholder's consent, and an open-flued gas appliance in the room calls for a spillage test.

Conservation areas are widespread across London, so a new extractor vent on a front wall may need permission, and leaseholders usually need the freeholder's written consent first.

Before you book cooker hood installation in Brent

  • Before choosing a hood for your Brent kitchen, find the nearest outside wall to the hob, because the shorter the duct run, the better the extraction.
  • Choose a hood at least as wide as your hob, and compare its stated extraction rate with the size of the room before you buy.
  • For an island hood in your Brent kitchen, settle the hood position before the ceiling is boarded, so timber supports can be added in the right place.
  • Check the minimum height above the hob in both the hood and hob instructions, and use the greater of the two figures.

Questions about cooker hood installation in Brent

How much does cooker hood installation cost in Brent?

For a like-for-like cooker hood swap, budget around £160 to £310 including VAT in Brent. That reflects typical costs in London; we confirm the actual figure in writing once we have measured up.

Do you work near Brent as well?

Yes. As well as Brent itself, we cover the rest of Greater London and nearby towns such as Wembley and Sudbury, Greater London. The process is the same wherever the kitchen is.

Why might a cooker hood need a spillage test?

Because a hood pulling air out of a room can draw fumes back down the flue of an open-flued gas appliance, such as some older boilers or gas fires. Where the kitchen, or a room open to it, has one, a Gas Safe registered engineer should carry out a spillage test with the hood running at full speed. Room-sealed boilers are not affected in the same way.

Should I choose a ducted or a recirculating cooker hood?

A ducted hood is usually more effective, because it takes steam, smoke and smells outside. A recirculating hood passes air through grease and carbon filters and returns it to the room, so it deals with grease and smells but not moisture, and another means of extract is usually needed. Recirculating suits kitchens with no practical duct route, and its carbon filters need replacing.

Does a cooker hood need a hole in the wall?

A ducted hood does. The usual route is a core-drilled hole through the nearest outside wall, with rigid ducting from the hood and an external grille sealed into the wall. Where the hob is far from an outside wall, the duct can sometimes run above the wall units or through a ceiling void. A recirculating hood needs no hole, but it removes no moisture.

Cooker hood installation in neighbouring towns

The same service is available a short drive from Brent, including:

Combine cooker hood installation with other work

Free survey visit

Book a free survey visit in Brent

We measure up, check walls, floors and service positions, and send an itemised written quote. Or get a guide price online in about two minutes.

Book a free survey visit

Tell us about the kitchen and the work. We will call to arrange a visit.

We use your details only to arrange your visit and quote. See our privacy notice.

Prefer to talk? 0800 088 6341

CallGuide price