Cooker hood installation · Greater London
Cooker hood installation in Golders Green
Cooker hood installation for Golders Green homes: ducted and recirculating cooker hoods fitted, with wall core drilling, ducting and an external grille. Every job starts with a free survey visit and a written quote.

Why cooker hood installation for a Golders Green home?
People in flats across Greater London sometimes rely on recirculating hoods because an outside vent needs consent from the building's owners, and want to know what else improves ventilation.
A new kitchen in a Golders Green home can move the hob away from the old vent, so the hood, the duct run and the wall grille all need rethinking together. Kitchens in every part of Golders Green are covered, and the survey visit is free wherever you are in Greater London.
What we cover for cooker hood installation in Golders Green
Here is what usually goes into cooker hood installation, adjusted to your Golders Green kitchen after we have measured it:
- Short, straight runs of rigid ducting wherever the route allows
- Island and ceiling hoods fixed into the ceiling structure by two people
- Hood fixed at the height set by the hood and hob manufacturers
- Power supply connected by an electrician and tested to BS 7671
- Core drilling through the outside wall and an external grille fitted and sealed
- Spillage test by a Gas Safe registered engineer where an open-flued appliance is present
Cooker hood installation prices in Golders Green
As a starting point for Golders Green, these ranges include VAT at 20% and allow for typical labour costs in London. Prices in London usually run above the national guide, mainly because labour and parking cost more.
| Typical project | Guide price |
|---|---|
| Like-for-like cooker hood swapSame position and ducting | £160–£310 |
| New ducted hood through an outside wallCore drilling, ducting run and external grille | £390–£1,200 |
| Island or ceiling hood installedTwo-person install, fixings to the ceiling structure | £390–£820 |
| Recirculating hood fittedNo ducting; carbon filters need replacing | £160–£390 |
Guide ranges cover fitting and connection with standard ducting through a straightforward wall; long or concealed duct runs, ceiling repairs, new electrical spurs, spillage tests and the hood itself are priced separately. Prices include VAT at 20%.
Local homes and their kitchens
The housing mix across Greater London includes Victorian and Edwardian terraces, conversion flats, mansion block flats and 1930s semis, so no two kitchen fits are quite alike. Victorian terraces often have a narrow galley beside the side return, while conversion flats and mansion blocks usually fit the kitchen into a small room or along one living-room wall.
Permit parking, red routes and flats without lifts are common, so parking suspensions, stair carries and lift bookings may need arranging before delivery day. London's mains water is hard, so limescale builds quickly on taps and boiling water taps, and a scale-reducing filter is worth planning in.
Do you need approval for cooker hood installation in Golders Green?
In England, Approved Document F guidance for kitchen extract is about 30 litres per second from a cooker hood extracting outside, or 60 litres per second from a fan elsewhere in the room. A recirculating hood does not remove moisture, so another means of extract is usually needed. A new vent through the outside wall of a flat may need planning permission and the freeholder's consent, and an open-flued gas appliance in the room calls for a spillage test.
Conservation areas are widespread across London, so a new extractor vent on a front wall may need permission, and leaseholders usually need the freeholder's written consent first.
Before you book cooker hood installation in Golders Green
- For an island hood in your Golders Green kitchen, settle the hood position before the ceiling is boarded, so timber supports can be added in the right place.
- Before choosing a hood for your Golders Green kitchen, find the nearest outside wall to the hob, because the shorter the duct run, the better the extraction.
- Replace the carbon filters in a recirculating hood as often as the manufacturer advises, and clean the grease filters regularly so the hood keeps working well.
- Keep the duct run short and straight with rigid ducting, because every bend and extra metre of flexible hose reduces how much air the hood moves.
Questions about cooker hood installation in Golders Green
How much does cooker hood installation cost in Golders Green?
For a like-for-like cooker hood swap, budget around £160 to £310 including VAT in Golders Green. That reflects typical costs in London; we confirm the actual figure in writing once we have measured up.
Do you cover all of Golders Green?
Yes. We work across Golders Green, including the NW11 postcode district, and nearby towns such as Kilburn and Finchley. Book a free survey visit and we will arrange a time that suits you.
Should I choose a ducted or a recirculating cooker hood?
A ducted hood is usually more effective, because it takes steam, smoke and smells outside. A recirculating hood passes air through grease and carbon filters and returns it to the room, so it deals with grease and smells but not moisture, and another means of extract is usually needed. Recirculating suits kitchens with no practical duct route, and its carbon filters need replacing.
Why might a cooker hood need a spillage test?
Because a hood pulling air out of a room can draw fumes back down the flue of an open-flued gas appliance, such as some older boilers or gas fires. Where the kitchen, or a room open to it, has one, a Gas Safe registered engineer should carry out a spillage test with the hood running at full speed. Room-sealed boilers are not affected in the same way.
Does a cooker hood need a hole in the wall?
A ducted hood does. The usual route is a core-drilled hole through the nearest outside wall, with rigid ducting from the hood and an external grille sealed into the wall. Where the hob is far from an outside wall, the duct can sometimes run above the wall units or through a ceiling void. A recirculating hood needs no hole, but it removes no moisture.
Also covering nearby towns
The same service is available a short drive from Golders Green, including:
- Cooker hood installation in Kilburn
- Cooker hood installation in Finchley
- Cooker hood installation in Muswell Hill
- Cooker hood installation in Friern Barnet
- Cooker hood installation in Willesden
- Cooker hood installation in Harlesden
- Cooker hood installation across Greater London