Cooker hood installation · Scotland
Cooker hood installation in Argyll and Bute
Cooker hood installation in Argyll and Bute starts with a free visit to measure up, then a written scope and quote before any work begins.
Thinking about cooker hood installation in Argyll and Bute?
If your Argyll and Bute house has thick solid walls, core drilling a neat hole for the duct takes the right equipment and careful positioning of the outside grille.
A new kitchen in an Argyll and Bute home can move the hob away from the old vent, so the hood, the duct run and the wall grille all need rethinking together.
What does cooker hood installation in Argyll and Bute include?
The exact scope is agreed after the survey, but a typical job in Argyll and Bute covers:
- Survey of the hob position, duct route, outside wall and any open-flued appliance
- Hood fixed at the height set by the hood and hob manufacturers
- Core drilling through the outside wall and an external grille fitted and sealed
- Short, straight runs of rigid ducting wherever the route allows
- Island and ceiling hoods fixed into the ceiling structure by two people
- Recirculating hoods fitted with carbon filters, and their limits explained
- Power supply connected by an electrician and tested to BS 7671
- Spillage test by a Gas Safe registered engineer where an open-flued appliance is present
How much does cooker hood installation cost in Argyll and Bute?
The figures below are guide prices for Argyll and Bute, including VAT and adjusted for typical costs across Scotland. The fixed price comes after we have measured up. Costs across Scotland tend to sit under UK averages, which these ranges reflect.
| Typical project | Guide price |
|---|---|
| Like-for-like cooker hood swapSame position and ducting | £110–£230 |
| New ducted hood through an outside wallCore drilling, ducting run and external grille | £280–£850 |
| Island or ceiling hood installedTwo-person install, fixings to the ceiling structure | £280–£590 |
| Recirculating hood fittedNo ducting; carbon filters need replacing | £110–£280 |
Guide ranges cover fitting and connection with standard ducting through a straightforward wall; long or concealed duct runs, ceiling repairs, new electrical spurs, spillage tests and the hood itself are priced separately. Prices include VAT at 20%.
Kitchens in homes across Argyll and Bute
Across Argyll and Bute you will often find Victorian villas, whitewashed cottages, tenement flats and post-war bungalows, and each shapes the kitchen differently. Victorian villas in Dunoon and Oban often have a separate scullery and a larger kitchen, while cottages and bungalows tend to have a compact room at the back.
Soft water is usual across Argyll and Bute, so limescale is rarely a concern, though rural homes on private supplies may need their own filtering. Long single-track roads are common, and some mainland addresses are quickest reached by ferry, so delivery dates, vehicle size and worktop lengths need planning around timetables and weather.
Villa kitchens are sometimes split between a main room and a former scullery, and joining them is a common project that needs a building warrant if the wall is load-bearing. Rural cottages are often off the gas grid, so cooking may be electric or run from LPG.
Rules for cooker hood installation in Argyll and Bute
In Scotland, standard 3.14 of the domestic Technical Handbook expects kitchens to have extract ventilation, and a recirculating hood alone does not remove moisture. Fitting an extractor fan or a ducted hood does not normally need a building warrant. In a flat, a new vent through a shared outside wall may need the other owners' agreement and planning permission, and a listed building may need listed building consent. Where the room has an open-flued gas appliance, a Gas Safe registered engineer should carry out a spillage test after the hood is fitted.
Parts of Cowal lie within Loch Lomond and The Trossachs National Park, and listed buildings or conservation areas may need consent for a new external vent.
Before you start
- For an island or ceiling hood, find out what is above the ceiling, as joists or added timbers are needed to carry the weight securely.
- If the kitchen has an open-flued boiler or gas fire, a Gas Safe registered engineer should carry out a spillage test after the hood is fitted.
- Keep the duct run short and straight with rigid ducting, because every bend and extra metre of flexible hose reduces how much air the hood moves.
- Choose ducted extraction where you can; a recirculating hood filters grease and smells but leaves the moisture from cooking in the room.
- If your Argyll and Bute home is listed, or in a building with strict rules on outside changes, check what is allowed before any hole is cut for a duct.
- Replace the carbon filters in a recirculating hood as often as the manufacturer advises, and clean the grease filters regularly so the hood keeps working well.
Questions about cooker hood installation in Argyll and Bute
How much does cooker hood installation cost in Argyll and Bute?
For a like-for-like cooker hood swap, budget around £110 to £230 including VAT in Argyll and Bute. That reflects typical costs in Scotland; we confirm the actual figure in writing once we have measured up.
Do you cover the whole of Argyll and Bute?
Yes, across mainland Argyll and Bute, including Dunoon and Oban. We do not currently cover the islands, such as Bute, Mull and Islay. Every job starts with a free survey visit and an itemised written quote.
Should I choose a ducted or a recirculating cooker hood?
A ducted hood is usually more effective, because it takes steam, smoke and smells outside. A recirculating hood passes air through grease and carbon filters and returns it to the room, so it deals with grease and smells but not moisture, and another means of extract is usually needed. Recirculating suits kitchens with no practical duct route, and its carbon filters need replacing.
How high should a cooker hood be above the hob?
At least the minimum distance given by the manufacturers. Both the hood and the hob instructions set a minimum gap between them, and where they differ the greater figure should be used. Gas hobs usually need more clearance than induction. A hood fitted too low is a fire risk, while one fitted much higher than recommended captures less steam.
Why might a cooker hood need a spillage test?
Because a hood pulling air out of a room can draw fumes back down the flue of an open-flued gas appliance, such as some older boilers or gas fires. Where the kitchen, or a room open to it, has one, a Gas Safe registered engineer should carry out a spillage test with the hood running at full speed. Room-sealed boilers are not affected in the same way.